Thanks to the smart monitoring platform, EC full series inverter products support remotely shutdown immediately when accident occurs. Setting parameters and FW update remotely, which makes PV plant O&M easier.
» Broken-code screen and 65K HD touch screen (optional)
» Multi-language customization
» PV reverse polarity protection.
» Wide output voltage range
» Battery-side soft starter
MODEL | HS1033EH24L | HS1033EH48L |
---|---|---|
Battery Voltage | 24Vdc | 48Vdc |
Battery Type | Lead-acid, lithium batteries, gel batteries, etc | |
Output | ||
Rated Output Power | 3600VA/3300W | |
Parallel Function | N/A | |
Rated Output Voltage | 230Vac ±4% | |
Rated Output Frequency | 50/60Hz (±0.3Adaptivelv) | |
Output Waveform | Pure sine wave | |
Max Efficiency(Peak) | 93.8% | |
Rated Current | 14.3A | |
Transfer Time | 10ms(Typical value) | |
PV Input | ||
Rated Power | 3600W | |
MPPT Voltage Range | 90 - 500Vdc | |
Max Input Voltage | 500Vdc | |
Max.Charging Current | 100A | 60A |
Mains/ Generator Input | ||
Max.Charging Current | 60A | 30A |
AC Input Voltage Range (UPS mode) | 170 - 280Vac,+2% | |
Frequency Range | (47.5/50Hz) ±0.3 / (57.5/63Hz) ±0.5 | |
Battery Input | ||
Voltage Range | 20 - 53Vdc | 40 - 60Vdc |
Max.Charging Current | 100A | 60A |
Default Charging Current | 30A | |
General Parameters | ||
Dimension (W*D*H/mm) | 372*269*100 | |
Installation Method | Wall-mounted | |
Weight (kg) | 7.2 | |
Communication Mode | RS485, Optional WIFI/4G | |
Protection function | Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection, High/Low Temp Protection | |
Operating Environment | ||
Operating Ambient Temperature | -25℃ - 60℃ (-40℃ - 45℃ Derating ) | |
Storage Ambient Temperature | -20℃ - 60℃ | |
Humidity | 5% - 95% Non-condensation | |
Altitude | 4000m (>2000m Derating) | |
Protection Degree | IP20 (For Indoor use only) | |
Certifications | ||
Certification | CE、RoHS | |
Certifications standard | IEC/EN 61000-6-1/3, EN 62920, IEC 62109-1, IEC 62109-2, IEC 62321 | |
Specifications are subject to change without advance notice. |
We offer 2 years warranty of the solar inverters and 5 years warranty optional, the maximum life of the inverter can be 10 years at most.
We are building warehouse and service centers in Nigeria, Pakistan, Iraq, Phlippines, you can get more details from “Support-Service” on the website.
IEC62109, IEC/EN62109-1/2, EN61000-6-1/3, UL 1741, CQC, etc,.
No, such modes are IP20, needs to be installed indoor.
93% as usual.
-Single phase 230VAC for residentail users;
-Three phase 380VAC for commercial users;
-Split phase 120&240VAC for US residential users;
-Three phase 480VAC for US commercial users.
Not really.
The noise of the inverter is less than 50dB, similar like the air conditioners working.
Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.
In general, solar inverters are very safe electrical devices, as long as they are properly installed by professionals and selected with good quality.
It depends on the installation and use environment of the inverter. Generally speaking, it is possible. However, it is necessary to strictly follow the original manufacturer’s instructions and must be repaired by professionals.