Technical Specifications

HC1030EH48L~HC1060EH48L Parameters

HC1030EH48L~HC1060EH48L Parameters

MODEL HC1030EH48L HC1040EH48L HC1050EH48L HC1060EH48L
PV Input
Max PV Input Power 6000W 4000W+4000W 5000W+5000W 6000W+6000W
Max PV Input Voltage 500Vdc
PV Input Startup voltage 90Vdc
MPPT Input Voltage 120 - 425Vdc
MPPT Full Load Voltage Range 335 - 425Vdc 235 - 425Vdc 295 - 425Vdc 350 - 425Vdc
PV Max Input Current 18A 26A 18A+18A
PV Short-circuit Current 18A+18A
Number of MPPT Strings per MPPT 1/1 2/1+1
AC Output
Rated Output Voltage 220V/230Vac
Output Frequency Range 50/60Hz(±0.5), Intelligent adaptive/Settable
Rated Off-grid current 15A 17.4A 21.8A 26.1A
Max Off-grid Power 3000W 4000W 5000W 6000W
Grid - tied Power 3000W
Output Power Type Single Phase, L - N/PE
Output Power Factor > 0.99 @ Rated power (Adjustable 0.8 leading - 0.8 lagging)
THDi <3%
Transfer Time <10ms
Off - grid Overload Capability 101% - 110%: 30s, > 110%: 3s
Battery Input
Battery Type Lead - acid, lithium batteries, gel batteries, etc
Battery Voltage 48Vdc(40V - 60V)
Max Discharge Current 75A 100A 110A 120A
Max Charging Current 60A 100A 110A 120A
Max Discharge Power 3000W 4000W 5000W 6000W
Max Charging Power 3000W 4000W 5000W 6000W
AC Input
Max. Input Power to Battery 3000W 4000W 5000W 6000W
Rated Input Voltage 150 - 280Vac (110 - 300V Optional)
Rated Input Frequency 50/60Hz(±0.5), Intelligent adaptive/Settable
Rated Input Current 15A 17.4A 21.8A 26.1A
Efficiency
Max PV Conversion Efficiency 97.6%
European Efficiency 96.5%
MPPT Efficiency > 99%
General Parameters
Display Touch Screen+LED
Communication Mode RS485/CAN, GPRS/WIFI/Bluetooth/4G/LAN(Optional)
Protection function Overvoltage over and undervoltage protection, Grid over and underfrequency protection, Output short circuit/overload protection, PV reverse connection alarm, Battery overcharge and overdischarge protection, Insulation impedance protection, Ground fault protection
Noise (dB) <55
Cooling Intelligent fan (IP68)
Operating Ambient Temperature -40℃ - 60℃ (>45℃ Derating )
Storage Ambient Temperature -20℃ - 60℃
Humidity 0 - 100% Non - condensation
Altitude 5000m (<2000m Derating )
Protection Degree IP65
Installation Method Wall - mounted
Dimension (W*D*H(mm)) 320*170*440
Gross Weight (kg) 12 14 14.5 15
Warranty 5 years standard
Certifications
Certification CE, RoHS
Certifications standard IEC/EN 61000 - 6 - 15, IEC/EN 61000 - 3 - 12, EN 62752, IEC 62470 - 1, IEC 62109 - 2, IEC 62331
Specifications are subject to change without advance notice.

FAQ

We offer 5 years warranty of the solar inverters and 10 years warranty optional, the maximum life of the inverter can be 20 years at most.

We are building warehouse and service centers in Nigeria, Pakistan, Iraq, Phlippines, you can get more details from “Support-Service” on the website.

IEC62109, IEC/EN62109-1/2, EN61000-6-1/3, EN50549, VDE4105, CEi 0-21, UL 1741, CSA C22.2 No. 107.1-01, CQC,  etc,.

The maximum PV conversion efficiency is 97.6%

-EU efficiency is 97%

-MPPT efficiency: >99%

-Single phase 230VAC for residentail users;

-Three phase 380VAC for commercial users;

-Split phase 120&240VAC for US residential users;

-Three phase 480VAC for US commercial users.

Not really.

The noise of the inverter is less than 50dB, similar like the air conditioners working

Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.

In general, solar inverters are very safe electrical devices, as long as they are properly installed by professionals and selected with good quality.

It depends on the installation and use environment of the inverter. Generally speaking, it is possible. However, it is necessary to strictly follow the original manufacturer’s instructions and must be repaired by professionals.