Split Phase Off-Grid Inverter

120Vac & 240Vac | 8.5-12kW | 2 MPPT

Remotely shutdown function

Smart Monitoring Platform

Thanks to the smart monitoring platform, EC full series inverter products support remotely shutdown immediately when accident occurs. Setting parameters and FW update remotely, which makes PV plant O&M easier.

»  Broken-code screen and 65K HD touch screen (optional)

»  Multi-language customization

»  PV reverse polarity protection.

»  Wide output voltage range

»  Battery-side soft starter

Technical Specifications

HS1030UH48L - HS1060UH48L Parameters

HS1030UH48L - HS1060UH48L Parameters

MODEL HS1030UH48L HS1040UH48L HS1050UH48L HS1060UH48L
Battery Voltage 48Vdc
Battery Type Lead-acid, lithium batteries, gel batteries, etc
Output
Rated Output Power 3500VA/3000W 4400VA/4000W 5500VA/5000W 6600VA/6000W
Rated Output Voltage 120Vac ±4%
Rated Output Frequency 50/60Hz (±0.5%Adjustive)
Output Waveform Pure sine wave
Max Efficiency(Peak) 92%
Rated Current 25A 35.3A 41.7A 50A
Transfer Time 10ms(Typical value)
PV Input
Max PV Input power 5000W 6000W 10000W 12000W
MPPT Voltage Range 90 - 400Vdc
Max PV Input Voltage 450Vdc
Max Charging Current 80A 80A 100A 120A
Mains/ Generator Input
Max Charging Current 50A 70A 80A 100A
AC Input Voltage Range (UPS mode) 90 - 140Vac ±2%
Frequency Range (47-53Hz) ±0.5 / (57-63Hz) ±0.5
Battery Input
Voltage Range 40 - 60Vdc
Max Charging Current 80A 80A 100A 120A
Default Charging Current 40A 40A 60A 60A
General Parameters
Dimension: W*D*H(mm) 530*245*470 420*140*405
Installation Method Wall-mounted
Weight (kg) 12 24
Communication Mode RS485/CAN, Optional WIFI/4G
Protection Function Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection
Operating Environment
Operating Ambient Temperature -40℃ - 60℃ (>45℃ Derating )
Storage Ambient Temperature -20℃ - 60℃
Humidity 0% - 95% Non-condensation
Altitude <2000m
Protection Degree IP20 (For indoor use only)
Certifications
Certification certificate CE/IEC 62109-2, FCC/CSA, RoHS
Certifications level En61000, C2
Specifications are subject to change without advance notice.
HS2085UH48L~HS2120UH48L Parameters
MODEL HS2085UH48L HS2105UH48L/P HS2114UH48L/P HS2120UH48L
Battery Voltage 40~60Vdc
Battery Type Lead-acid, lithium batteries, gel batteries, etc
Output
Rated Output Power 8500W 10500W 11400W 12000W
Parallel Function N/A L:N/A ; P: Yes, up to 10 units L:N/A ; P: Yes, up to 10 units N/A
Rated Output Voltage 120/240Vac
Rated Output Frequency 50/60Hz Intelligent adaptive/configurable
Output Waveform Pure sine wave
Max Efficiency(Peak) 92%
Rated Current 35.4A 43.7A 47.5A 50.0A
Transfer Time 10ms (Typical value)
PV Input
Rated Power 6000W+6000W 7500W+7500W 7500W+7500W 7500W+7500W
MPPT Voltage Range 90~500Vdc
Max Input Voltage 500Vdc
Max Charging Current 180A±5A 200A±5A 200A±5A 200A±5A
Number of MPPT / Strings per MPPT 2/1+1
Mains/ Generator Input
Max Charging Current 100A 120A 120A 120A
AC Input Voltage Range (APL mode) 90~140Vac, ±2%
Frequency Range (47~55Hz) ±0.3 / (57~65Hz) ±0.3
Battery Input
Voltage Range 40~60Vdc
Max Charging Current 180±5A 200±5A 200±5A 200±5A
Default Charging Current 60A
General Parameters
Dimension (W*D*H mm) 620*140*465
Installation Method Wall-mounted
Weight (kg) 26
Communication Mode RS485/CAN Optional WIFI/4G
Protection Function Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection, High/Low Temp Protection, PV Reverse Connection Alarm
Operating Environment
Operating Ambient Temperature -25℃~60℃ ( >45℃ Derating )
Storage Ambient Temperature -20℃~60℃
Humidity 5%~95% Non-condensation
Altitude 4000m ( >2000m Derating )
Protection Degree IP20 (For indoor use only)
Certifications
Certification FCC, UL
Certifications Standard FCC 47 CFR Part 15, UL1741, TSCA, CA65

FAQ

We offer 2 years warranty of the solar inverters and 5 years warranty optional, the maximum life of the inverter can be 10 years at most.

We are building warehouse and service centers in Nigeria, Pakistan, Iraq, Phlippines, you can get more details from “Support-Service” on the website.

EC62109, IEC/EN62109-1/2, EN61000-6-1/3, UL 1741, CQC,  etc,.

No, such modes are the IP20, needs to be installed indoor.

The maximum PV conversion efficiency is 97.6% at most, but 93% as usual

-Single phase 230VAC for residentail users;

-Three phase 380VAC for commercial users;

-Split phase 120&240VAC for US residential users;

-Three phase 480VAC for US commercial users.

Not really.

The noise of the inverter is less than 50dB, similar like the air conditioners working

Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.

Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.

It depends on the installation and use environment of the inverter. Generally speaking, it is possible. However, it is necessary to strictly follow the original manufacturer’s instructions and must be repaired by professionals.