MODEL | HS1030UH48L | HS1040UH48L | HS1050UH48L | HS1060UH48L |
---|---|---|---|---|
Battery Voltage | 48Vdc | |||
Battery Type | Lead-acid, lithium batteries, gel batteries, etc | |||
Output | ||||
Rated Output Power | 3500VA/3000W | 4400VA/4000W | 5500VA/5000W | 6600VA/6000W |
Rated Output Voltage | 120Vac ±4% | |||
Rated Output Frequency | 50/60Hz (±0.5%Adjustive) | |||
Output Waveform | Pure sine wave | |||
Max Efficiency(Peak) | 92% | |||
Rated Current | 25A | 35.3A | 41.7A | 50A |
Transfer Time | 10ms(Typical value) | |||
PV Input | ||||
Max PV Input power | 5000W | 6000W | 10000W | 12000W |
MPPT Voltage Range | 90 - 400Vdc | |||
Max PV Input Voltage | 450Vdc | |||
Max Charging Current | 80A | 80A | 100A | 120A |
Mains/ Generator Input | ||||
Max Charging Current | 50A | 70A | 80A | 100A |
AC Input Voltage Range (UPS mode) | 90 - 140Vac ±2% | |||
Frequency Range | (47-53Hz) ±0.5 / (57-63Hz) ±0.5 | |||
Battery Input | ||||
Voltage Range | 40 - 60Vdc | |||
Max Charging Current | 80A | 80A | 100A | 120A |
Default Charging Current | 40A | 40A | 60A | 60A |
General Parameters | ||||
Dimension: W*D*H(mm) | 530*245*470 | 420*140*405 | ||
Installation Method | Wall-mounted | |||
Weight (kg) | 12 | 24 | ||
Communication Mode | RS485/CAN, Optional WIFI/4G | |||
Protection Function | Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection | |||
Operating Environment | ||||
Operating Ambient Temperature | -40℃ - 60℃ (>45℃ Derating ) | |||
Storage Ambient Temperature | -20℃ - 60℃ | |||
Humidity | 0% - 95% Non-condensation | |||
Altitude | <2000m | |||
Protection Degree | IP20 (For indoor use only) | |||
Certifications | ||||
Certification certificate | CE/IEC 62109-2, FCC/CSA, RoHS | |||
Certifications level | En61000, C2 | |||
Specifications are subject to change without advance notice. |
MODEL | HS2085UH48L | HS2105UH48L/P | HS2114UH48L/P | HS2120UH48L |
---|---|---|---|---|
Battery Voltage | 40~60Vdc | |||
Battery Type | Lead-acid, lithium batteries, gel batteries, etc | |||
Output | ||||
Rated Output Power | 8500W | 10500W | 11400W | 12000W |
Parallel Function | N/A | L:N/A ; P: Yes, up to 10 units | L:N/A ; P: Yes, up to 10 units | N/A |
Rated Output Voltage | 120/240Vac | |||
Rated Output Frequency | 50/60Hz Intelligent adaptive/configurable | |||
Output Waveform | Pure sine wave | |||
Max Efficiency(Peak) | 92% | |||
Rated Current | 35.4A | 43.7A | 47.5A | 50.0A |
Transfer Time | 10ms (Typical value) | |||
PV Input | ||||
Rated Power | 6000W+6000W | 7500W+7500W | 7500W+7500W | 7500W+7500W |
MPPT Voltage Range | 90~500Vdc | |||
Max Input Voltage | 500Vdc | |||
Max Charging Current | 180A±5A | 200A±5A | 200A±5A | 200A±5A |
Number of MPPT / Strings per MPPT | 2/1+1 | |||
Mains/ Generator Input | ||||
Max Charging Current | 100A | 120A | 120A | 120A |
AC Input Voltage Range (APL mode) | 90~140Vac, ±2% | |||
Frequency Range | (47~55Hz) ±0.3 / (57~65Hz) ±0.3 | |||
Battery Input | ||||
Voltage Range | 40~60Vdc | |||
Max Charging Current | 180±5A | 200±5A | 200±5A | 200±5A |
Default Charging Current | 60A | |||
General Parameters | ||||
Dimension (W*D*H mm) | 620*140*465 | |||
Installation Method | Wall-mounted | |||
Weight (kg) | 26 | |||
Communication Mode | RS485/CAN Optional WIFI/4G | |||
Protection Function | Over/Under Voltage Protection, Over/Under Frequency Protection, AC Output Short Circuit Protection, AC Output Overload Protection, High/Low Temp Protection, PV Reverse Connection Alarm | |||
Operating Environment | ||||
Operating Ambient Temperature | -25℃~60℃ ( >45℃ Derating ) | |||
Storage Ambient Temperature | -20℃~60℃ | |||
Humidity | 5%~95% Non-condensation | |||
Altitude | 4000m ( >2000m Derating ) | |||
Protection Degree | IP20 (For indoor use only) | |||
Certifications | ||||
Certification | FCC, UL | |||
Certifications Standard | FCC 47 CFR Part 15, UL1741, TSCA, CA65 |
We offer 2 years warranty of the solar inverters and 5 years warranty optional, the maximum life of the inverter can be 10 years at most.
We are building warehouse and service centers in Nigeria, Pakistan, Iraq, Phlippines, you can get more details from “Support-Service” on the website.
EC62109, IEC/EN62109-1/2, EN61000-6-1/3, UL 1741, CQC, etc,.
No, such modes are the IP20, needs to be installed indoor.
The maximum PV conversion efficiency is 97.6% at most, but 93% as usual
-Single phase 230VAC for residentail users;
-Three phase 380VAC for commercial users;
-Split phase 120&240VAC for US residential users;
-Three phase 480VAC for US commercial users.
Not really.
The noise of the inverter is less than 50dB, similar like the air conditioners working
Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.
Yes, but much lower even than the phones, we have detail introduction in the Technical Topics.
It depends on the installation and use environment of the inverter. Generally speaking, it is possible. However, it is necessary to strictly follow the original manufacturer’s instructions and must be repaired by professionals.