Solar Panels

PERC | TOPCON | HJT | Tier 1
600-660W

Remotely shutdown function

Smart Monitoring Platform

Thanks to the smart monitoring platform, EC full series inverter products support remotely shutdown immediately when accident occurs. Setting parameters and FW update remotely, which makes PV plant O&M easier.

e407689d64bda4b8fa7636c9ea1a372

»  Up to 26% Efficiency.

»  Single/Dual Glass for All Scenarios.

»  Bloomberg Tier 1 | MW Projects | Certified Quality.

 

Technical Specifications

625–650W PV Module Specifications

625–650W PV Module Specifications

Electrical Parameters at STC
Model SPDG625-N156R10 SPDG630-N156R10 SPDG635-N156R10 SPDG640-N156R10 SPDG645-N156R10 SPDG650-N156R10
Maximum Power (Pmax/W) 625 630 635 640 645 650
Maximum Power Voltage (Vmp/V) 36.17 36.32 36.48 36.63 36.78 36.93
Maximum Power Current (Imp/A) 17.28 17.35 17.41 17.48 17.54 17.60
Open Circuit Voltage (Voc/V) 43.85 44.00 44.15 44.30 44.45 44.60
Short Circuit Current (Isc/A) 18.36 18.42 18.48 18.54 18.60 18.66
Module Efficiency (%) 22.1 22.3 22.4 22.6 22.8 22.9
Electrical Parameters at NOCT
Model SPDG625-N156R10 SPDG630-N156R10 SPDG635-N156R10 SPDG640-N156R10 SPDG645-N156R10 SPDG650-N156R10
Maximum Power (Pmax/W) 464 468 472 476 480 484
Maximum Power Voltage (Vmp/V) 34.0 34.1 34.2 34.3 34.4 34.5
Maximum Power Current (Imp/A) 13.65 13.73 13.80 13.87 13.95 14.02
Open Circuit Voltage (Voc/V) 41.3 41.4 41.5 41.6 41.7 41.8
Short Circuit Current (Isc/A) 14.77 14.83 14.89 14.95 15.01 15.07
Temperature Coefficient
Temperature Coefficient of Pmax -0.30% / °C
Temperature Coefficient of Voc -0.25% / °C
Temperature Coefficient of Isc +0.045% / °C
Nominal Operating Cell Temperature (NOCT) 45 ± 2°C

* STC: Irradiance 1000 W/m², Cell temperature 25°C, AM 1.5. * NOCT: Irradiance 800 W/m², Ambient temperature 20°C, Wind speed 1 m/s.

FAQ

10 years warranty of products and additional 15 years warranty of performance

Normally YES, you can check the details in the Technical Topics.

Yes, based on the weather stiuation, 20%~80% of the rated power as usual.

Not exactly.

Efficiency is a key factor in determining solar panel size.
The higher the efficiency, the greater the power a solar panel can achieve for the same size. That is all.

Not really, after half a century of development, the power generation efficiency of solar panels can reach 30% of the cost of coal-fired power generation.

Yes.

With the advancement of technology and the promotion of government policies, the solar panel recycling industry is developing rapidly

You can follow us and check the details on the Technical Topics on this website.

The installation of a single solar panel usually takes 1-2 hours.

You can check the details on Technical Topics on this website.

You can follow us and check on the Technical Topics on this website.